In Reply to: RE: Tre, do you implement and 'heroic' regulation with the filament as that seems to yield marked improvement~nT posted by Tre' on November 02, 2023 at 07:08:28
A question to see if I understand this.
My tube amp has 100k input (100k from grid to ground). If I series a .01uF cap on the input, it will start roll off at 150Hz?
Follow Ups:
The -3db down point of the 6db per octave high pass filter created by the capacitor working into the 100k ohm resistor would be 159Hz.Here's the math.
-3db point = 159155 / (cap value in uf X resistance value in ohms)
Tre'
Have Fun and Enjoy the Music
"Still Working the Problem"
Edits: 11/05/23
Thanks, that's what I needed to know