Tubes Asylum Questions about tubes and gear that glows. FAQ |
|
In Reply to: Slow start/soft start posted by bmotorcycle on March 22, 2006 at 15:11:29:
Use a CL70 thermistor (inrush limiter) in series instead of a resistor. The CL70 is rated at 16 Ohms @ 4 amps cold resistance, and the resistance will drop to about 1 Ohm in fifteen seconds or less.The perfect soft-start for your amp, and only costs $1.39, and is available at www.mouser.com (stock #527-CL70).
Regards,
Mike
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- Re: Slow start/soft start - Mike Burrows 15:48:10 03/22/06 (4)
- Re: Slow start/soft start - bmotorcycle 16:34:59 03/22/06 (3)
- Re: Slow start/soft start - Mike Burrows 16:47:26 03/22/06 (2)
- Re: Slow start/soft start - bmotorcycle 16:54:41 03/22/06 (1)
- Re: Slow start/soft start - Mark Bos 18:30:23 03/22/06 (0)