RE: Your challenge is

Indeed. Cheever also came up with a metric that included SPL because the ear/brain masking extent (i.e. what harmonics and how much) changes with SPL.

This is why low SPL is more critical than high SPL because masking is less effective, particularly for high order harmonics even at very low levels. They also tend to be about the same regardless of amp output in a feedback type amplifier. It is also probably why low level resolution and soundstage/imaging are most affected by the negative effects of high order distortion and negative feedback.