The CORD is flat surface between the end-points of the ARC facing the wall. The ARC is the curved reflective surface facing in the room.

Just to be clear, I mounted them horizontally (in a single centered line) to disperse vertically like depicted on the right side of the picture.

Normally, they are mounted vertically (in multiples) to disperse horizontally (left side of picture) which causes unwanted focused lens effects instead of even dispersion patterns.

My goal was to attenuate AND delay the 1st reflection by dispersing it across a 180 degree reflection pattern in addition to lengthen its travel path (delay its arrival simulating a wider room) by turning portions of the dispersion into 2nd, 3rd, 4th, ... order reflections.

REW will show the dispersion as redistributed lower amplitude peaks indicating the energy is still in the room but decentralized pushed lower into the decay field.


.